MC1488 |
RFQ for MC1488 |
![]() |
| Technical/Catalog Information | MC1488D |
| Vendor | ON Semiconductor |
| Category | Integrated Circuits (ICs) |
| Number of Drivers/Receivers | 4/0 |
| Type | Driver |
| Voltage - Supply | 15V |
| Package / Case | 14-SOIC (3.9mm Width), 14-SOL |
| Packaging | Tube |
| Protocol | RS232 |
| Lead Free Status | Contains Lead |
| RoHS Status | RoHS Non-Compliant |
| Other Names | MC1488D MC1488D |
| Product | Manufacturers | Pack | D/C |
| MC1488 | - | SMD | 94+ |
Teletypewriter/RS-232C terminal to MC6850 ACIA interface (courtesy Motorola Semiconductor Products Inc.).
The MC1488, SN55188, and SN75188 are monolithic quadruple line drivers designed to interface data terminal equipment with data communications equipment in conformance with ANSI EIA/TIA-232-E using a diode in series with each supply-voltage terminal as shown under typical applications.
The SN55188 is characterized for operation over the full military temperature range of 55°C to 125°C. The MC1488 and SN75188 are characterized for operation from 0°C to 70°C.
Features |
| ·Meet or Exceed the Requirements of ANSI EIA/TIA-232-E and ITU Recommendation V.28·Designed to Be Interchangeable With Motorola MC1488·Current-Limited Output: 10 mA Typical·Power-Off Output Impedance: 300 W Minimum·Slew Rate Control by Load Capacitor·Flexible Supply Voltage Range·Input Compatible With Most TTL Circuits |
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VCC+ at (or below) 25°C free-air temperature (see Notes 1 and 2) . . . . . . . . . . . . . . . . . 15 V
Supply voltage, VCC at (or below) 25°C free-air temperature (see Notes 1 and 2) . . . . . . . . . . . . . . . 15 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V to 7 V
Output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . 15 V to 15 V
Continuous total power dissipation (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: SN55188 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55°C to 125°C
MC1488, SN75188 . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Case temperature for 60 seconds, FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or N package . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J or W package . . . . . . . . . . . . . . . . . . 300°C
† Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolut